1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface 1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface 1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface 1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface 1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface

Large Image :  1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Model Number: FFR
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2455pcs/month
Detailed Product Description
Type: Compression Force Load Cell Capacity: 10kg 20kg 50kg 100kg 200kg 500kg 1000kg
Usage: Thrust Force Measurement Force Direction: Compression
Mounting: Flange-to-flange Output: Analog Sensor

1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface

Flanged Compression Load Cell FFR is made of stainless steel utilizing strain gauge technology to deliver mV/V output from the full wheatstone bridge. Flange Type Thrust Force Sensor FFR offers 0-10kg / 0-20kg / 0-50kg / 0-100kg / 0-200kg / 0-500kg / 0-1000kg seven rated measuring ranges to choose from, Column type thrust force transducer FFR is designed for compression force measurement with flange-to-flange configuration. Flange Mounting Compression Force Sensor FFR is suitable for applications such as automated control process, cylinder thrust measurement, assembly force monitoring, bearing press fit measurement, welding clamping force control, hand press force verification, fixture clamp force test and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide load cell custom design service to meet requirements of different applications.

Compression_Load_Cell_With_Flange_Mounting_Surface

Specifications

Capacity

10kg / 20kg / 50kg / 100kg / 200kg / 500kg / 1000kg

100N / 200N / 500N / 1kN / 2kN / 5kN / 10kN
20lb / 45 lb / 110lb / 220 lbs / 440lbf / 1100lbf / 2200lb

Rated output 1.5 mV/V
Excitation 3-15V
Zero balance ±0.1mV/V
Nonlinearity ±0.3% R.O.
Hysteresis ±0.3% R.O.
Nonrepeatability ±0.1% R.O.
Creep(5min) ±0.1% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 750±100 ohms
Output resistance 700±10 ohms
Insulation resistance >5000M ohms
Ingress protection IP65
Material of element Stainless steel
Cable Ø3*3000mm 4-core shielded
Wiring code

Red--Excitation+    Black--Excitation-

Green--Signal+   White--Signal-

 

1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface

Compression_Load_Cell_With_Flange_Mounting

A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.

Output signal of load cell and amplifier:
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output of Flange Mounted Thrust Load Cell FFR is normally around 1.5mV/V.
Power supply of Flange Type Thrust Load cell FFR is normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of Compression Type Thrust Force Sensor FFR is normally within 0…+22.5mV.
Example one: Flanged Thrust Force Transducer FFR-200kg with 1.5mV/V sensitivity powered by 5V DC,the output range is 0mV...+7.5mV.
Example two: Flange Type Thrust Force Sensor FFR-1000kg with 1.5mV/V rated output powered by 10V DC,the output range is 0mV...+15mV.

Compression_Load_Cell_With_Display_Unit

The mV/V output from the wheatstone bridge sometimes can hardly be processed directly, a signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.
Example one: Flange Type Compression Load Cell FFR-500kg working with amplifier FSC(0-10V)-24V,the Load-Voltage relationship will be 0-500kg compression force VS 0-10V output, which is linear regardless of the measurement error, 1V output corresponds to 50kg compression load, 2V output corresponds to 100kg compression load, and so on.
Example two: Miniature Column Type Force Sensor FFR-100kg working with amplifier FSC(4-20mA)-24V,the Force-Current relationship will be 0-100kg compression force VS 4-20mA output, which is linear regardless of the measurement error, 4mA output corresponds to “0” load, 5.6mA output corresponds to 10kg compression load, 12mA output corresponds to 50kg compression load, and so on.

1t 500kg 200kg 100kg 50kg 20kg 10kg Compression Load Cell With Flange Mounting Surface

Compression_Load_Cell_With_Flange_SurfaceCompression_Load_Cell_With_Flat_Surface

Ordering code Measurement Range Force direction
FFR-10kg 0-100N / 0-10kgf Compression
FFR-20kg 0-200N / 0-20kgf
FFR-50kg 0-500N / 0-50kgf
FFR-100kg 0-1kN / 0-100kgf
FFR-200kg 0-2kN / 0-200kgf
FFR-500kg 0-5kN / 0-500kgf
FFR-1000kg 0-10kN / 0-1000kgf

 

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us